Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Nuclear Medicine ; (6): 50-54, 2009.
Article in Chinese | WPRIM | ID: wpr-642645

ABSTRACT

Objective Insulin autoantibody (IAA) is known to exist in sera of type 1 diabetes mellitus (T1DM) patients and pre-T1DM individuals. The aim of this study was to establish a novel microtiter plate radioimmunoassay (RIA) for IAA and evaluate its clinical value. Methods Diluted 125Ⅰ-insulin was mixed with 5 ul serum samples in a 96-well microtiter plate and then incubated for 72 h on an orbital plate shaker (4℃). The immunocomplexes were transferred to another protein a coated Millipore plate, and then the plate was washed with Tri-Buffered Saline Tween-20 (TBT) buffer. Counts per minute (CPM) was measured with liquid scintillation and luminescence counter. The positive cut-off point of IAA index was defined as ≥0.06 based on the 99-percentile of the distribution in 317 healthy individuals. The specificity and sensitivity of the assay were calculated from the samples provided by the fourth Diabetes Autoantibodies Standardization Program (DASP 2005). The IAA levels were determined in 71 T1 DM and 551 newly diagnosed type 2 diabetes (T2DM) patients, and 317 healthy controls. The t test, non-parametric test, x2 test and linear correlation analysis were performed on the data using SPSS 11.5 software. The concordance rate was estimated with Kappa value. Results (1) The optimized testing condition was described as 2×104 CPM of 125Ⅰ-insulin, 5 ul serum sample and slowly horizontal shaking for 72 h. (2) The intra-assay CV was 4.8%-8.9% and inter-assay CV was 6.4%-10.5%. Based on DASP 2005 samples, the specificity and sensitivity of the assay were 97% (97/100) and 50% (25/50), respectively. Ninety-six serum samples with different IAA levels were selected and tested to compare between our new method and a domestic IAA RIA kit. The results showed that the IAA indices from the two methods were positively correlated (r= 0.678, P<0.001). The concordance rate was 72.9 %(Kappa value=0.402). There were 25 samples with discordant results, which were positive for IAA titer using the corresponding microtiter plate RIA but negative using the novel RIA kit. (3) In TIDM group the positive rate of IAA was 19.7% (16/71), higher than the healthy controls (0.9%, x2=54.36, P<0.001). The subgroup of T1DM children (with 0-9 years) showed the highest IAA positive rate (55.6% ,x2=4.85, P<0.05). In T2DM group the frequency of IAA was 1.5% (8/551), which had no significant difference comparing with that of healthy controls (x2= 0.95, P >0.05). Conclusions Our proposed microtiter plate RIA method for IAA is highly sensitive and specific, likely to be feasible for clinical application. The frequency of IAA is high in children with T1DM.

2.
Chinese Journal of Nuclear Medicine ; (6): 339-343, 2008.
Article in Chinese | WPRIM | ID: wpr-642325

ABSTRACT

Objective The purpose of this study was to develop a high-throughput micro-plate radiobinding assay (RBA) of glutamic acid decarboxylase antibody (GAD-Ab) and to evaluate its clinical application. Methods 35labeled GAD65 antigen was incubated with sera for 24 h on a 96-well plate, and then transferred to the Millipore plate coated with protein A, which was washed with 4℃ PBS buffer, and then counted by a liquid scintillation counter. The GAD-Ab results were expressed by WHO standard unit (U/ml). A total of 224 healthy controls, 162 patients with type 1 diabetes mellitus(T1DM) and 210 patients with newly diagnosed type 2 diabetes (T2DM) were recruited. A total of 119 TI DM and healthy cases with gradually changing GAD-Ab levels were selected to compare the consistency of micro-plate RBA with conventional radioligand assay (RLA). Blood samples were obtained from the peripheral vein and finger tip in 32 healthy controls, 35 T1DM and 24 T2DM patients, and tested with micro-plate RBA and then compared with the conventional RLA to investigate the reliability of finger tip sampling. Linear correlation,student's t-test, variance analysis and receiver operating characteristic (ROC) curve were performed using SPSS 11.5. Results (1) The optimized conditions of micro-plate RBA included 2 μl serum incubated with3 ×104 counts/min 35S-GAD for 24 h under slow vibration, antigen-antibody compounds washed 10 times by 4℃ PBS buffer, and radioactivity counted with Optiphase Supermix scintillation liquid. (2)The intra-batch CV of the micro-plate RBA was 3.8%- 10.2%, and the inter-batch CV was 5.6%- 11.9%. The linearity analysis showed a good correlation when the GAD-Ab in serum samples ranged from 40.3 to 664 U/ml and the detection limit of measurement was 3.6 U/ml. The results from Diabetes Autoantibody Standardization Program (DASP) 2005 showed that the sensitivity and specificity for GAD-Ab were 78% (39 positive among 50 new-onset T1DM) and 98% (2 positive among 100 healthy controls). The results of GAD-Ab obtained with micro-plate RBA and RLA were closely correlated (r=0.915,P<0.001) with a high concordance level of 97.5% and a Kappa value of 0.95. (3)TI DM and T2DM patients showed higher positive rates for GAD-Ab than the healthy controls(46.9% and 5.2% vs 0.89% ,X2=123.5 and 10. 1 ,P <0.001 and <0.01, respectively). (4)The consistency of GAD-Ab measurement with RBA using finger tip blood and RLA measurement using venous blood was 96.7% (r =0.946,P <0.001, Kappa value: 0.905). Conclusions The micro-plate RBA of GAD-Ab has high sensitivity, specificity and reproducibility, and can be measured with finger tip blood sampling. It might be a better alternative for clinical practice.

SELECTION OF CITATIONS
SEARCH DETAIL